Analytical Sciences


Abstract − Analytical Sciences, 33(1), 29 (2017).

Simultaneous Determination of Warfarin and Aspirin Contents in Biological Fluids Using Excitation-Emission Matrix Fluorescence Coupled with a Second-order Calibration Method
Rong XIAO, Hai-Long WU, Yong HU, Xiao-Li YIN, Hui-Wen GU, Zhi LIU, Tong WANG, Xiao-Dong SUN, and Ru-Qin YU
State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
In the present work, a practical method that combines excitation-emission matrix fluorescence with a second-order calibration method based on an alternating trilinear decomposition (ATLD) algorithm was developed in order to simultaneously and directly determine the contents of warfarin (WAR) and aspirin (ASA) in human plasma and urine samples, even in the presence of unknown interferences. With the pre-estimated component number of 4, the obtained average spiked recoveries were 105.4 ± 7.8 and 104.2 ± 8.3% for WAR, 96.5 ± 2.8 and 91.2 ± 2.3% for ASA in human plasma and urine samples, respectively. Furthermore, the figures of merit were calculated and also inter- and intra-day experiments were performed that proved the proposed method is of great significance to the monitoring of clinical administration and also being a simple sample pretreatment at low-cost.