Abstract − Analytical Sciences, 26(8), 907 (2010).
Voltammetric Determination of Ferulic Acid by Didodecyldimethylammonium Bromide/Nafion Composite Film-modified Carbon Paste Electrode
Liqiang LUO,* Xia WANG,* Qiuxia LI,* Yaping DING,* Jianbo JIA,** and Dongmei DENG*
*College of Sciences, Shanghai University, 99 Shangda Road, Shanghai 200444, P. R. China
**State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
**State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China
A simple and rapid method for the determination of ferulic acid in pharmaceutical formulations by didodecyldimethylammonium bromide (DDAB)/Nafion composite film-modified carbon paste electrode is presented. The electrochemical behavior of ferulic acid at the proposed electrode was investigated by cyclic voltammetry and a well-defined oxidation peak was observed at +0.44 V versus saturated calomel electrode in 0.1 M acetate buffer (pH 5.5) solutions. Some experimental parameters affecting the electrochemical response of the modified electrode were optimized. Under optimal conditions, the oxidation peak currents of ferulic acid increase linearly with the concentration of ferulic acid in the range from 2.0 × 10−6 to 1.2 × 10−4 M with a detection limit of 3.9 × 10−7 M (S/N = 3). The proposed method was successfully applied to the determination of ferulic acid in pharmaceutical tablets.
J-STAGE:
View this article in J-STAGE