Analytical Sciences


Abstract − Analytical Sciences, 23(3), 365 (2007).

Direct Simultaneous Determination for Ultratrace As, Se and Sb in River Water with Graphite-Furnace Atomic Absorpion Spectrometry by TiO2-Slurry Sampling
Liang ZHANG,*,** Yukitoki MORITA,* Kenji YOSHIKAWA,* and Akinori ISOZAKI*
*Department of Materials and Applied Chemistry, College of Science and Technology, Nihon University, 1-8 Kanda-Surugadai, Chiyoda, Tokyo 101-8308, Japan
**Department of Applied Chemistry, College of Science, Xi'an University of Architecture and Technology, Yanta Road 13, Xi'an, Shannxi, China
A simple analytical method was established for the simultaneous multielement determination of As, Se and Sb in river water with GF-AAS using TiO2-slurry sampling. Titanium dioxide (TiO2, <0.5 µm) was applied as a sorbent to separate and concentrate these elements in a sample solution (100 - 300 ml); after filtration, a slurry was prepared with the solid phase and 5.0 ml of ultrapure water. In order to apply to river-water samples, the effect of TiO2 in atomization, the effect of organic species of their metal and the interference of foreign ions were investigated. The proposed method was applied to JSAC 0302 and river water.